ASCABLE - Cat.: Communication & multimedia - Sec.:Telecommunications
Applicable Standard: ISO / IEC 11801-2, ISO/IEC 64156-5, EIA/TIA 568B, EN-50173
Cable consisting of rigid CCA conductors insulated in polyethylene and PVC outer cover.
Data transmission cable for structured cabling networks (LAN), in horizontal and secondary facilities. Guaranteed a life of 25 years as long as the temperature conditions, radii of curvature and proper installation (channeled out of power circuits) are respected.
TYPE (nº Pairs x AWG) |
ELECT. RESIST.
(Max.) W/km |
INBALANCE ELECT. RESIST. (Max.)
% |
CAP. BETWEEN COND. PAIR
pF/m |
PROPAGATION RATE
% |
CHARAC. IMPEDANCE
Ω |
OUTER Ø (Approx.) mm |
4x2x23 | 93,8 | 2 | < 48 | 65 | 100 ± 15 | 7,2 ± 0,30 |
Frequency MHz |
Atenuation
(nominal) dB/100 m |
SRL
(min.) dB |
NEXT
dB |
ELFEXT
dB/100 m |
PS-NEXTdB |
PS-ELFEXT dB/100 m |
1 | 2,02 | 20 | 74,3 | 67,8 | 72,3 | 64,8 |
4 | 3,78 | 23 | 65,27 | 55,76 | 63,27 | 52,76 |
8 | 5,32 | 24,5 | 60,75 | 49,74 | 58,75 | 46,74 |
10 | 5,95 | 25 | 59,3 | 47,8 | 57,3 | 44,8 |
16 | 7,55 | 25 | 56,24 | 43,72 | 54,24 | 40,72 |
20 | 8,47 | 25 | 54,78 | 41,78 | 52,78 | 38,78 |
25 | 9,51 | 24,3 | 53,33 | 39,84 | 51,33 | 36,84 |
31,25 | 10,67 | 23,6 | 51,88 | 37,9 | 49,88 | 34,9 |
62,5 | 15,38 | 21,5 | 47,36 | 31,88 | 45,36 | 28,88 |
100 | 19,8 | 20,1 | 44,3 | 27,8 | 42,3 | 24,8 |
250 | 32,84 | 17,3 | 38,33 | 19,8 | 36,3 | 16,8 |
Drum | ![]() |